Treatment systems
CE and CEN series specifications
Full design data and structural drawings for every model, residential through commercial.
CE series
Certified to NSF/ANSI 40. Hydraulic loads from 500 to 6,000 gallons per day.
| Model | CE5 | CE7 | CE10 | CE14 | CE21 | CE30 | CE6KG |
|---|---|---|---|---|---|---|---|
| Hydraulic load (GPD) | 500 | 700 | 1,000 | 1,350 | 1,900 | 2,700 | 6,000 |
| Effluent | NSF 40 test effluent, average CBOD 11 mg/L, TSS 12 mg/L | ||||||
| Blower | |||||||
| Blower model | 80RII | 80RII | 100RII | 150RII | 200RII | 150RII ×2 | 200RII ×4 |
| Normal pressure (kPa) | 15 | 15 | 18 | 20 | 20 | 20 | 20 |
| Airflow (CFM) | 2.8 | 2.8 | 3.5 | 5.3 | 7.0 | 10.6 | 28.0 |
| Power use (kWh/day) | 1.2 | 1.2 | 1.7 | 2.7 | 3.7 | 5.4 | 14.8 |
| Tank | |||||||
| Material | Fiber-reinforced plastic | ||||||
| Height (in) | 62 | 66 | 74 | 78 | 82 | 88 | 88 |
| Length (in) | 85 | 96 | 99 | 119 | 153 | 184 | 435 |
| Width (in) | 44 | 50 | 57 | 69 | 73 | 79 | 116 |
| Weight (lbs) | 397 | 463 | 705 | 926 | 1,168 | 1,543 | 2,900 |
| Inlet invert (in) | 49 | 53 | 61 | 62 | 65 | 71 | 67 |
| Outlet invert (in) | 47 | 51 | 59 | 59.5 | 63 | 69 | 64 |
| Access ports | 3 | 3 | 3 | 3 | 3 | 3 | 7 |
| Total volume (gal) | 545 | 749 | 1,069 | 1,498 | 2,252 | 3,199 | 7,267 |
| Drawings | |||||||
| Structural drawing | PDF · CAD | PDF · CAD | PDF · CAD | PDF · CAD | PDF · CAD | PDF · CAD | |
Source: FujiClean USA design specification table, March 2023. TN removal data for CE systems is available from field testing — contact FujiClean USA.
CEN series
Certified to NSF/ANSI 40 and 245, with enhanced nitrogen reduction. Specified where local regulations require nitrogen removal.
| Model | CEN5 | CEN7 | CEN10 | CEN14 | CEN21 | CEN50 |
|---|---|---|---|---|---|---|
| Hydraulic load (GPD) | 500 | 700 | 1,000 | 1,350 | 1,900 | 4,500 |
| Effluent | NSF 40/245 test effluent, average CBOD 5 mg/L, TSS 6 mg/L, TN 10 mg/L | |||||
| Blower | ||||||
| Blower model | 80RII | 100RII | 150RII | 200RII | 150RII ×2 | — |
| Normal pressure (kPa) | 15 | 18 | 20 | 20 | 20 | — |
| Airflow (CFM) | 2.8 | 3.5 | 5.3 | 7.0 | 10.6 | — |
| Power use (kWh/day) | 1.2 | 1.7 | 2.7 | 3.7 | 5.4 | — |
| Tank | ||||||
| Material | Fiber-reinforced plastic | |||||
| Height (in) | 66 | 74 | 78 | 82 | 88 | 110 |
| Length (in) | 96 | 99 | 119 | 153 | 184 | 304 |
| Width (in) | 49 | 57 | 69 | 73 | 79 | 99 |
| Weight (lbs) | 463 | 705 | 926 | 1,168 | 1,543 | 2,400 |
| Inlet invert (in) | 53 | 61 | 62 | 65 | 71 | 86 |
| Outlet invert (in) | 51 | 59 | 59.5 | 63 | 69 | 84 |
| Access ports | 3 | 3 | 3 | 3 | 3 | 5 |
| Total volume (gal) | 749 | 1,069 | 1,498 | 2,252 | 3,199 | 7,020 |
| Drawings | ||||||
| Structural drawing | PDF · CAD | PDF · CAD | PDF · CAD | PDF · CAD | PDF · CAD | — |
| Design package | CAD | CAD | CAD | CAD | CAD | — |
Source: FujiClean USA design specification table, March 2023. Contact FujiClean USA regarding CEN50 availability. Design packages courtesy of Advanced Wastewater Solutions LI; these are large CAD files, 8 to 10 MB each.
Blowers
Aeration is supplied by an external FujiMAC RII blower sited at grade rather than inside the tank. Model selection follows from the tank size.
- FujiMAC 80RII — CE5, CE7, CEN5
- FujiMAC 100RII — CE10, CEN7
- FujiMAC 150RII — CE14, CEN10, and paired on CE30 and CEN21
- FujiMAC 200RII — CE21, CEN14, and in fours on CE6KG
Leaching systems and pump stations
Integrated Septic Solutions will provide materials and solutions for all approved engineered leaching systems and pump stations.
Designing a system?